Skip to content

ATC-BZN · Attenuation

Attenuation tank on an operational RAF base

An attenuation tank at RAF Brize Norton, lined in 0.6mm HDPE geomembrane on a live, secure airbase.

Location
RAF Brize Norton
Region
Oxfordshire
Sector
Defence
Completed
2026
The HDPE-wrapped attenuation tank at RAF Brize Norton
Rec · ATC-BZNRAF Brize Norton — Defence

Attenuation · RAF Brize Norton

RAF

Ref
ATC-BZN
Region
Oxfordshire
Sector
Defence
Year
2026
01

What we did

58m × 2m of geotextile and 40m × 2.5m of 0.6mm HDPE geomembrane, welded panel to panel, the crates built inside and the wrap closed and sealed around the pipe connections.

02

The tricky bits

Access on a secure base is planned in advance, and the inspection crates arrived late, so the programme had to flex around them. The base welds were pressure-tested and marked up before anything was covered.

03

What we delivered

A lined, wrapped and base-tested tank delivered inside the base's access rules.

04

Materials

The tank was lined in 0.6mm HDPE geomembrane, from 2.5m-wide rolls, over 2m-wide geotextile. HDPE is less conformable than LLDPE, the membrane we fit on most tanks, so the wrap is dressed to the crate block with care at the corners. Every joint was heat-welded. None were taped.

05

Sign-off

Once the inspection crates arrived and went in, the wrap was closed and the installation was signed off on site at the end of April 2026, with the weld test record and QA documentation handed over.

Project datasheetATC-BZN
Membrane
0.6mm HDPE, welded
Geotextile
58 × 2m
QA
Base weld pressure-tested
Sector
Defence
System · Attenuation Tanks

On site · RAF Brize Norton

Geotextile wrapped over the tank at RAF Brize Norton
Rec · ATC-BZNRAF Brize Norton — Defence
Base weld pressure test marked 'Brize Norton' on the membrane
Rec · ATC-BZNRAF Brize Norton — Defence
Next in the log · LIN-HS2

HS2 pond lining in 1mm HDPE

Tell us about your project

Quote back within one working day